Checklist · Plant setup

WHO-GMP Compliant OSD Plant: Equipment and Design Requirements

By the Hello Pharma Editorial Team · Last updated 19 November 2026 · 3 min read

Short answer

WHO-GMP requires equipment to be located, designed, constructed, adapted and maintained to suit its operations, minimise error and allow effective cleaning. For an OSD plant this translates into stainless steel contact parts with smooth, crevice-free surfaces, dust containment and extraction, calibrated instruments, documented qualification (IQ, OQ, PQ), and HVAC that controls pressure, humidity and cross-contamination. Specify these features in the user requirement specification for every machine.

What the WHO principles say about equipment

The WHO GMP main principles set the standard most national inspectorates follow for oral solids. Their equipment chapter says equipment must be located, designed, constructed, adapted and maintained to suit the operations carried out, and its layout and design must minimise the risk of errors and allow effective cleaning and maintenance to avoid cross-contamination, build-up of dust or dirt and any adverse effect on product quality.

Requirements mapped to machine features

GMP expectationFeature to specify
Contact surfaces must not react with or add to the productSS 316L product contact parts, FDA-compliant seals and gaskets, material certificates
Easy, effective cleaningSmooth polished surfaces, no dead legs, tool-free dismantling, wash-in-place where useful
Prevent cross-contamination and dust build-upClosed transfer, dust extraction points, sealed drives, containment for potent products
Lubricants must not contaminate productFood-grade lubricants and physical separation of drive and product zones
Accurate measuring and weighingCalibrated instruments with certificates and a defined range
Equipment status must be clearStatus labelling and, for automated machines, electronic status and logs
Reliable recordsBatch reports, audit trails and access control in controls (21 CFR Part 11 if supplying the US)
Fitness for purpose provenSupplier support for DQ, FAT, SAT, IQ, OQ and PQ documentation

Facility and utilities

  • HVAC: filtered air, pressure differentials between areas, humidity control for hygroscopic products and dust control, following the WHO HVAC guideline for non-sterile products.
  • Water: purified water generation, storage and distribution suitable for granulation and final rinse.
  • Compressed air: oil-free and filtered where it contacts product.
  • Premises: smooth, cleanable walls, floors and ceilings; separate areas for dispensing, production, packing, quarantine and QC.
  • Flows: logical material and personnel flows to prevent mix-ups and contamination.

Documents to demand from suppliers

  1. Design specification against your user requirement specification.
  2. Material certificates for contact parts and surface finish reports.
  3. Calibration certificates for instruments.
  4. FAT and SAT protocols and reports.
  5. IQ and OQ protocols, drawings, manuals and spare parts lists.
  6. Software documentation and validation support for automated controls.

Companies listed in the Hello Pharma supplier directory

The Hello Pharma supplier directory lists 115 companies relevant to this guide, grouped below by machine type or category. Each name links to the company's directory entry, with a description, technologies, location and website. Companies confirmed against their websites or public listings appear first in each group.

Inclusion is not an endorsement or ranking. Many categories are inferred from company names and segments, so confirm capabilities, approvals and service reach directly with each supplier. Search all 1,232 companies.

Granulation (48)

ACG Worldwide Solid Dosage Consumables and Machinery; Anish Pharma Equip Pvt. Ltd; Bectochem Consultant & Engineers Pvt. Ltd.; Bowman & Archer Pharma Machines (India) Pvt.Ltd; Cadmach Machinery Co. Pvt Ltd; Fabtech Technologies International Ltd.; Gansons Limited; Indo German Pharma Engineers; Parle Global Technologies Pvt. Ltd.; Prism Pharma Machinery; Saan Engineers Pvt Ltd; Solace Engineers (Mktg) Pvt. Ltd.; SSPM Systems & Engineers; Sunsai Pharma Equipments Pvt. Ltd.; Tapasya Engineering Works Pvt Ltd; Allegro Pharmachem Equipments; Ambica Engineering Works; Astro Mech; BEW Engineering Pvt. Ltd.; Bombay Pharma Equipments Pvt Ltd; Bright Pharma Engineering Private Limited; Brilliant Process Machinery Pvt. Ltd.; Brinda Pharma Technologies Pvt Ltd.; CEMACH; Dumra Machines; Gem Pharma Machineries; Glatt Group; Grovers International; Helios Concrew Machines; HLE Engineers Pvt. Ltd.; Imperial Pharmachines Pvt Ltd; Indo Rama Engineers; Laxmi Pharma Machines; LEISTUNG ENGINEERING PVT LTD; Mack Pharmatech Pvt. Ltd.; Mecwell Pharma Machinery Pvt. Ltd.; Omega Pharma Machinery; Pankaj Industries; Pharma Mech Machineries; Promp+tech Pharma Equipments (India) Pvt Ltd and 8 more.

Open the full entries: Oral solid dosage equipment list filtered to granulation · Engineering and validation services list filtered to granulation · Sterile, injectable and liquid equipment list filtered to granulation

Tablet presses (21)

ACG Worldwide Solid Dosage Consumables and Machinery; Cadmach Machinery Co. Pvt Ltd; Concept Engineering; Fluidpack; Karnavati Engineering; Parle Global Technologies Pvt. Ltd.; Prism Pharma Machinery; Solace Engineers (Mktg) Pvt. Ltd.; Accura Pharmaquip Pvt Ltd; Dumra Machines; Grovers International; Helios Concrew Machines; Imperial Pharmachines Pvt Ltd; Kothari Pharma Technologies Private Ltd.; Kunal Machines; LE - Born Technomech; NEO Machine Mfg Co LTD; Omega Pharma Machinery; Propix Technologies Pvt Ltd; Richards Industries; Saimach Pharmatech Pvt. Ltd..

Open the full entries: Oral solid dosage equipment list filtered to tablet presses

Coating (25)

ACG Worldwide Solid Dosage Consumables and Machinery; Anish Pharma Equip Pvt. Ltd; Bectochem Consultant & Engineers Pvt. Ltd.; Bowman & Archer Pharma Machines (India) Pvt.Ltd; Gansons Limited; Indo German Pharma Engineers; Koroth Systems Pvt. Ltd.; Prism Pharma Machinery; S.K. Pharma Machinery Pvt Ltd; Solace Engineers (Mktg) Pvt. Ltd.; SSPM Systems & Engineers; Sunsai Pharma Equipments Pvt. Ltd.; Tapasya Engineering Works Pvt Ltd; The United Engineering Company; Bombay Pharma Equipments Pvt Ltd; Bright Pharma Engineering Private Limited; Brinda Pharma Technologies Pvt Ltd.; Glatt Group; Grovers International; HLE Engineers Pvt. Ltd.; Mack Pharmatech Pvt. Ltd.; Promp+tech Pharma Equipments (India) Pvt Ltd; R.P. Products Pharma Equipments Pvt Ltd; Ramashary Pharma Machinery Pvt. Ltd.; Spraytech Systems India Pvt. Ltd..

Open the full entries: Oral solid dosage equipment list filtered to coating · Sterile, injectable and liquid equipment list filtered to coating

Cleanroom, HVAC and containment (31)

Airtech Systems India Pvt. Ltd.; Gandhi Automations Pvt. Ltd.; GMP Technical Solutions Pvt Ltd; A.C. Humidin Air Systems Pvt. Ltd.; Aastha Cleanroom Systems Private Limited; Ace Hygiene Product Pvt Ltd (Alfaa UV); Bry-Air (Asia) Private Limited; Camfil Air Filtration India Pvt. Ltd.; Clean Coats Pvt. Ltd.; Contec Airflow Pvt. Ltd.; Esco Biotech Pvt. Ltd.; Freudenberg Gala Household Product Pvt Ltd; Hvax Technologies Pvt. Ltd.; Idealin Fogging Systems; Industrial Equipwash Inc; Integrated Cleanroom Technology Pvt. Ltd.; Khimsaria Associates; Khosla Profil Pvt. Ltd.; Kleantech Engineering Systems Pvt. Ltd.; Lindstrom Services India Pvt Ltd; Moreschi Asia Doors P Ltd; Nicomac Clean Rooms Far East Pvt Ltd; Nilfisk India Pvt Ltd; Pharma Air Modular System; Radiant Enterprise; Russair Technologies Pvt. Ltd.; Sanosil Biotech Pvt. Ltd.; Shree Aerodynamic Products; Suntec Teknopak Cleanrooms & Containments; Synergy Thrislington; Ultramax Hydrojet Pvt Ltd.

Open the full entries: Cleanroom, HVAC and containment list

Purified water and WFI (14)

Christ Nishotech Water Systems Pvt Ltd; D.D. Enterprises; Fabtech Technologies International Ltd.; GMP Technical Solutions Pvt Ltd; Hydropure Systems Pvt. Ltd.; Indo German Pharma Engineers; Machinfabrik Industries Pvt. Ltd.; Pharmalab India Pvt Ltd; Praj HiPurity Systems Limited.; Swiss Engineering Pvt Ltd; Aquamech Engineering Corporation; Indu IonPure India Pvt. Ltd.; Sanpure Systems Pvt Ltd; Wab India Pvt. Ltd..

Open the full entries: Water and utilities list filtered to purified water and wfi · Sterile, injectable and liquid equipment list filtered to purified water and wfi · Engineering and validation services list filtered to purified water and wfi · Process plant equipment list filtered to purified water and wfi

Validation services (13)

Airtech Systems India Pvt. Ltd.; Bliss-ca Technologies; D.D. Enterprises; Salesworth Synergies LLP; Thermolab Scientific Equipments Pvt Ltd; Autocal Solutions Pvt. Ltd.; Hyde Engineering + Consulting; June Enterprises Pvt Ltd.; Metina Pharmconsulting Private Limited; Pratham Technologies Pvt. Ltd.; Sergusa Solutions Pvt. Ltd.; SpectrumPharmaTECH Consultants Pvt. Ltd.; TechnoValue Solutions Pvt Ltd.

Open the full entries: Engineering and validation services list filtered to validation services · Lab and analytical list filtered to validation services · Packaging machinery list filtered to validation services · Cleanroom, HVAC and containment list filtered to validation services

Frequently asked questions

Is WHO-GMP certification issued for equipment?

No. WHO-GMP applies to the manufacturing site and its systems. Equipment suppliers can describe machines as designed to meet GMP, but compliance is demonstrated by the manufacturer through qualification and use.

Is SS 304 acceptable for OSD equipment?

SS 316L is the usual standard for product contact parts. SS 304 is common for non-contact parts and frames. Follow your risk assessment and customer requirements.

What HVAC standard applies to non-sterile OSD areas?

WHO's guideline on HVAC systems for non-sterile pharmaceutical products is widely used. It covers risk assessment, filtration, pressure differentials, humidity and dust control.

Does WHO-GMP require computerised system validation?

Yes, computerised systems that affect product quality must be validated, with data integrity controls. US-bound products also need to meet 21 CFR Part 11.

Related guides

Sources

  1. WHO GMP main principles (TRS 986, Annex 2), WHO
  2. WHO HVAC guidelines for non-sterile products, Part 2 (TRS 1019, Annex 2)
  3. Basic principles of GMP: equipment, WHO training module
  4. 21 CFR Part 211, Subpart D Equipment, eCFR

This guide is general information to support decisions and is not engineering, validation or regulatory advice for a specific project.

Ready to read pharma differently?

Join the Hello Pharma community for editorial, intelligence and engineering reference from pharma manufacturing.