Guide · Plant setup

Scaling Up from Pilot to Commercial Tablet Production: Equipment Decisions

By the Hello Pharma Editorial Team · Last updated 19 November 2026 · 3 min read

Short answer

Scale-up goes most smoothly when commercial equipment works on the same operating principle as the pilot equipment, for example a high shear granulator at both scales, because regulators treat equipment of the same class and subclass as the same design. The parameters that do change with scale, such as impeller tip speed, spray rate, airflow, fill depth and press dwell time, must be translated deliberately and confirmed with engineering and validation batches.

Why equipment class matters

The US FDA's SUPAC guidance for immediate release products groups manufacturing equipment by class, meaning operating principle, and subclass, meaning design characteristic. Equipment in the same class and subclass is considered to have the same design and operating principle. Changing a V-blender from one manufacturer to another is not a change in principle; changing from a V-blender (diffusion mixing) to a ribbon blender (convection mixing) is.

The practical lesson: choose pilot equipment that has a commercial-scale equivalent of the same class and subclass, ideally from the same equipment family, so scale-up is a change of size rather than of principle. In 2014 the FDA's addendum removed its lists of specific equipment models but kept the class and subclass approach.

What changes with scale, step by step

StepParameters that change with scaleCommon scaling approach
High shear granulationImpeller and chopper speed, binder addition rate, wet massing time, end pointKeep impeller tip speed or Froude number similar; use power or torque for end point
Fluid bed dryingInlet airflow and temperature, bed depth, drying timeScale airflow by distributor area; control by product temperature and outlet conditions
MillingScreen size, speed, feed rateKeep screen size and tip speed; confirm particle size distribution
BlendingFill level, rotation speed, blend timeKeep fill level within the working range; scale revolutions rather than minutes
CompressionTurret speed, dwell time, pre-compression, feeder speedMatch dwell time between pilot and commercial presses
Film coatingSpray rate, atomising air, pan speed, airflow, batch loadScale spray rate to batch size and pan geometry; keep the environmental equivalency of the bed

Planning scale-up equipment

  • Map each pilot unit operation to its commercial equivalent before buying either.
  • Choose pilot presses that can use the same tooling standard and reach commercial dwell times.
  • Prefer families of granulators, fluid beds and coaters with documented scale-up ratios from the supplier.
  • Keep the same control strategy across scales: same in-process tests and end-point measurements.
  • Budget for engineering batches before validation, especially for coating and granulation.

From scale-up to validation

  1. Use development and pilot data to identify critical process parameters and their ranges.
  2. Run engineering batches at commercial scale to confirm the translated parameters.
  3. Qualify the commercial equipment (IQ, OQ, PQ).
  4. Run process validation batches and plan continued process verification.
  5. For approved products, check the regulatory filing level of the scale change in each market.

Companies listed in the Hello Pharma supplier directory

The Hello Pharma supplier directory lists 85 companies relevant to this guide, grouped below by machine type or category. Each name links to the company's directory entry, with a description, technologies, location and website. Companies confirmed against their websites or public listings appear first in each group.

Inclusion is not an endorsement or ranking. Many categories are inferred from company names and segments, so confirm capabilities, approvals and service reach directly with each supplier. Search all 1,232 companies.

Tablet presses (21)

ACG Worldwide Solid Dosage Consumables and Machinery; Cadmach Machinery Co. Pvt Ltd; Concept Engineering; Fluidpack; Karnavati Engineering; Parle Global Technologies Pvt. Ltd.; Prism Pharma Machinery; Solace Engineers (Mktg) Pvt. Ltd.; Accura Pharmaquip Pvt Ltd; Dumra Machines; Grovers International; Helios Concrew Machines; Imperial Pharmachines Pvt Ltd; Kothari Pharma Technologies Private Ltd.; Kunal Machines; LE - Born Technomech; NEO Machine Mfg Co LTD; Omega Pharma Machinery; Propix Technologies Pvt Ltd; Richards Industries; Saimach Pharmatech Pvt. Ltd..

Open the full entries: Oral solid dosage equipment list filtered to tablet presses

Granulation (48)

ACG Worldwide Solid Dosage Consumables and Machinery; Anish Pharma Equip Pvt. Ltd; Bectochem Consultant & Engineers Pvt. Ltd.; Bowman & Archer Pharma Machines (India) Pvt.Ltd; Cadmach Machinery Co. Pvt Ltd; Fabtech Technologies International Ltd.; Gansons Limited; Indo German Pharma Engineers; Parle Global Technologies Pvt. Ltd.; Prism Pharma Machinery; Saan Engineers Pvt Ltd; Solace Engineers (Mktg) Pvt. Ltd.; SSPM Systems & Engineers; Sunsai Pharma Equipments Pvt. Ltd.; Tapasya Engineering Works Pvt Ltd; Allegro Pharmachem Equipments; Ambica Engineering Works; Astro Mech; BEW Engineering Pvt. Ltd.; Bombay Pharma Equipments Pvt Ltd; Bright Pharma Engineering Private Limited; Brilliant Process Machinery Pvt. Ltd.; Brinda Pharma Technologies Pvt Ltd.; CEMACH; Dumra Machines; Gem Pharma Machineries; Glatt Group; Grovers International; Helios Concrew Machines; HLE Engineers Pvt. Ltd.; Imperial Pharmachines Pvt Ltd; Indo Rama Engineers; Laxmi Pharma Machines; LEISTUNG ENGINEERING PVT LTD; Mack Pharmatech Pvt. Ltd.; Mecwell Pharma Machinery Pvt. Ltd.; Omega Pharma Machinery; Pankaj Industries; Pharma Mech Machineries; Promp+tech Pharma Equipments (India) Pvt Ltd and 8 more.

Open the full entries: Oral solid dosage equipment list filtered to granulation · Engineering and validation services list filtered to granulation · Sterile, injectable and liquid equipment list filtered to granulation

Coating (25)

ACG Worldwide Solid Dosage Consumables and Machinery; Anish Pharma Equip Pvt. Ltd; Bectochem Consultant & Engineers Pvt. Ltd.; Bowman & Archer Pharma Machines (India) Pvt.Ltd; Gansons Limited; Indo German Pharma Engineers; Koroth Systems Pvt. Ltd.; Prism Pharma Machinery; S.K. Pharma Machinery Pvt Ltd; Solace Engineers (Mktg) Pvt. Ltd.; SSPM Systems & Engineers; Sunsai Pharma Equipments Pvt. Ltd.; Tapasya Engineering Works Pvt Ltd; The United Engineering Company; Bombay Pharma Equipments Pvt Ltd; Bright Pharma Engineering Private Limited; Brinda Pharma Technologies Pvt Ltd.; Glatt Group; Grovers International; HLE Engineers Pvt. Ltd.; Mack Pharmatech Pvt. Ltd.; Promp+tech Pharma Equipments (India) Pvt Ltd; R.P. Products Pharma Equipments Pvt Ltd; Ramashary Pharma Machinery Pvt. Ltd.; Spraytech Systems India Pvt. Ltd..

Open the full entries: Oral solid dosage equipment list filtered to coating · Sterile, injectable and liquid equipment list filtered to coating

Engineering services (24)

D.D. Enterprises; Fabtech Technologies International Ltd.; Anvay Pharma Systems Pvt. Ltd.; Aspire India; Bio Pharm Engineering; Camfield Engineers; Centech Engineers Pvt. Ltd.; EMCO Engineering; Hexagon Product Development Pvt. Ltd.; Hyde Engineering + Consulting; Landsky Engineers Pvt. Ltd.; M K Teknology 1 Pvt. Ltd.; MRC Systems FZE; Orbit Technologies Pvt. Ltd.; Parth Engineers & Consultant; Pharmatech Engineering Company; Pharmintech Turnkey Solutions Pvt Ltd; Pratham Technologies Pvt. Ltd.; Rihim Pharma Consultancy Pvt. Ltd.; Skytech Systems (India) Pvt.Ltd.; SMMS Engineering Systems Pvt. Ltd.; SpectrumPharmaTECH Consultants Pvt. Ltd.; SRJ Engineers Pvt. Ltd.; Vishva Protech Pvt. Ltd..

Open the full entries: Engineering and validation services list filtered to engineering services

Frequently asked questions

What is the biggest risk in scaling up tablet production?

Changing equipment operating principle between scales, for example moving from a planetary mixer to a high shear granulator, which can change granule properties. Keeping the same class and subclass of equipment reduces that risk.

How is dwell time matched between presses?

Dwell time depends on punch head flat size and turret linear speed. Choose a pilot press, or a compaction simulator, that can run at the commercial press's dwell time for the same tooling.

Do scale changes need regulatory approval?

For approved products, scale changes are post-approval changes. The US FDA's SUPAC guidance sets the documentation level by size of change and equipment principle; other regions have their own variation rules.

How many engineering batches are needed?

There is no fixed number. Most companies run one to three engineering batches at commercial scale before validation, depending on product complexity and how well pilot data predicts commercial behaviour.

Related guides

Sources

  1. SUPAC-IR/MR manufacturing equipment addendum (archived FDA guidance)
  2. Change control: new FDA expectations for equipment changes, ECA Academy
  3. Best practices for post-approval CMC changes: SUPAC, US FDA presentation
  4. Critical tablet press design considerations, KORSCH (IPT)

This guide is general information to support decisions and is not engineering, validation or regulatory advice for a specific project.