Guide · Compliance and validation

FAT and SAT for Pharma Machinery: A Practical Guide

By the Hello Pharma Editorial Team · Last updated 19 November 2026 · 3 min read

Short answer

The factory acceptance test (FAT) proves at the supplier's works that the machine meets the specification before shipping; the site acceptance test (SAT) proves it still does after installation with real utilities. Good FATs use approved scripts traced to the URS, test with product or placebo at full speed, challenge alarms, interlocks and data integrity features, and record deviations with agreed fixes. Well-documented FAT and SAT results can be reused in IQ and OQ under EU GMP Annex 15, saving time.

FAT vs SAT

AspectFATSAT
LocationSupplier's factoryBuyer's site
PurposeConfirm design and build before shipmentConfirm installation and performance with site utilities
Typical testsDocuments, dimensions, functions, alarms, software, performance with placeboUtility connections, repeat key functions, integration with line and site systems
Fixing defectsCheaper; supplier's experts on handMore costly; may delay start-up

Writing test scripts

  1. Trace every test to a URS or functional requirement in a traceability matrix.
  2. Write clear steps, expected results and acceptance criteria before testing.
  3. Include document checks: drawings, certificates, software versions.
  4. Test normal operation, limits, alarms, interlocks and power failure recovery.
  5. Challenge data integrity: user rights, audit trail, clock, backup; see Part 11 checklist.
  6. Run performance tests with product, placebo or test materials at target speed and duration.
  7. Record deviations, agree corrective actions and retest.

Common FAT failures

  • Documents incomplete or not matching the machine as built.
  • Machine not ready: FAT becomes a debugging session.
  • Performance tested briefly or without representative materials.
  • Software versions changed after FAT without control.
  • Missing change parts for all formats.
  • No buyer QA review, so results cannot be leveraged in IQ and OQ.

Planning tips

  • Agree FAT readiness criteria and send a pre-FAT checklist.
  • Send the right team: engineering, production and QA.
  • Ship enough placebo or product for meaningful runs.
  • Decide in advance which FAT tests will be reused in IQ and OQ.
  • Freeze software after FAT and manage changes formally.

Related: supplier document pack.

Companies listed in the Hello Pharma supplier directory

The Hello Pharma supplier directory lists 40 companies relevant to this guide, grouped below by machine type or category. Each name links to the company's directory entry, with a description, technologies, location and website. Companies confirmed against their websites or public listings appear first in each group.

Inclusion is not an endorsement or ranking. Many categories are inferred from company names and segments, so confirm capabilities, approvals and service reach directly with each supplier. Search all 1,232 companies.

Validation services (13)

Airtech Systems India Pvt. Ltd.; Bliss-ca Technologies; D.D. Enterprises; Salesworth Synergies LLP; Thermolab Scientific Equipments Pvt Ltd; Autocal Solutions Pvt. Ltd.; Hyde Engineering + Consulting; June Enterprises Pvt Ltd.; Metina Pharmconsulting Private Limited; Pratham Technologies Pvt. Ltd.; Sergusa Solutions Pvt. Ltd.; SpectrumPharmaTECH Consultants Pvt. Ltd.; TechnoValue Solutions Pvt Ltd.

Open the full entries: Engineering and validation services list filtered to validation services · Lab and analytical list filtered to validation services · Packaging machinery list filtered to validation services · Cleanroom, HVAC and containment list filtered to validation services

Engineering services (31)

Adam Fabriwerk; Bectochem Consultant & Engineers Pvt. Ltd.; D.D. Enterprises; Fabtech Technologies International Ltd.; GMP Technical Solutions Pvt Ltd; Praj HiPurity Systems Limited.; Propack Technologies Pvt Ltd; Snowbell Machines Pvt Ltd; Tofflon (India) Pvt. Ltd; Anvay Pharma Systems Pvt. Ltd.; Aspire India; Bio Pharm Engineering; Camfield Engineers; Centech Engineers Pvt. Ltd.; EMCO Engineering; Hexagon Product Development Pvt. Ltd.; Hyde Engineering + Consulting; Landsky Engineers Pvt. Ltd.; M K Teknology 1 Pvt. Ltd.; MRC Systems FZE; Orbit Technologies Pvt. Ltd.; Parth Engineers & Consultant; Pharmatech Engineering Company; Pharmintech Turnkey Solutions Pvt Ltd; Pratham Technologies Pvt. Ltd.; Rihim Pharma Consultancy Pvt. Ltd.; Skytech Systems (India) Pvt.Ltd.; SMMS Engineering Systems Pvt. Ltd.; SpectrumPharmaTECH Consultants Pvt. Ltd.; SRJ Engineers Pvt. Ltd.; Vishva Protech Pvt. Ltd..

Open the full entries: Engineering and validation services list filtered to engineering services · Sterile, injectable and liquid equipment list filtered to engineering services · Water and utilities list filtered to engineering services · Cleanroom, HVAC and containment list filtered to engineering services

Frequently asked questions

What is the difference between FAT and SAT?

FAT is done at the supplier's factory before shipment; SAT is done at the buyer's site after installation, with real utilities and integration.

Is FAT mandatory?

EU GMP Annex 15 says equipment, especially novel or complex equipment, may be evaluated at the vendor before delivery where applicable. Most companies do FATs for critical equipment.

Can FAT replace IQ or OQ?

Parts of it can be leveraged into IQ and OQ if assessed and justified and nothing changed during shipment and installation.

Who should attend a FAT?

Engineering, production and quality representatives from the buyer, plus the supplier's engineers and software specialists.

Related guides

Sources

  1. EU GMP Annex 15 qualification and validation, European Commission
  2. Driving the future of commissioning and qualification, ISPE
  3. New EU GMP Annex 15 revision (FAT leverage), ECA Academy
  4. ISPE Baseline Guide 5 second edition, CAI

This guide is general information to support decisions and is not engineering, validation or regulatory advice for a specific project.

Ready to read pharma differently?

Join the Hello Pharma community for editorial, intelligence and engineering reference from pharma manufacturing.